X-ray Generators ODEL (Italy)
What is an X-ray Generator?
An X-ray generator or X-ray device is a complex set of electrical, electronic and digital components. Its main function is to supply power to the X-ray tube, control and stabilize its operation, and protect against overload during diagnostic examinations. The generator converts the voltage of a three-phase network (380/400 V) or single-phase (220/230 V) into high-voltage voltage from 40 to 150 kV, which is supplied to the X-ray tube. As a result, X-ray radiation is generated, which illuminates the controlled object.
ODEL X-ray Generators
X-ray diagnostics is an important element of modern medicine, and X-ray generators play a critical role in providing high-quality medical images. The Italian company ODEL SRL began its activity in 1951 as a manufacturer of high-power transformers. In 1961, ODEL presented its first X-ray device - a step-up transformer, which was installed on a control console developed by the company in the same period. This device became the basis for the current range of radiological devices.
ODEL X-ray generators have been certified since 1993 in accordance with European Union standards, confirming their compliance with high safety and quality requirements.
ODEL is known as a manufacturer of high-quality products that meet strict safety and reliability standards in the industry.
ODEL Products: X-ray Generators
Three-phase generators for radiography and fluoroscopy R306.4x series - PROGRAM HF US3 :
These generators are designed specifically for digital imaging and offer a wide range of capabilities. Available models have powers 40, 50, 65, 80 and 100 kW, which allows them to be adapted to various diagnostic tasks.
Three-phase generators for radiography and fluoroscopy of the R306.3x series - ENDEAVOUR :
Compact and universal generators designed for radiography (R version), fluoroscopy (RF version) or digital diagnostics (HRF version). ENDEAVOUR generators offer a variety of customization options to meet specific X-ray machine requirements. Models are available in 40, 50, 65, 80 and 100 kW.
ENDEAVOUR generators offer a variety of customization options to meet specific X-ray machine requirements. Models with the capacity of 40, 50, 65, 80 and 100 kW are available.
Technical characteristics of the most commonly used ENDEAVOUR generators
| R306.34 | R306.35 | R306.36 | R306.37 |
Power supply | 3 phases, 400 V ±10%, 50 ±1 Hz |
Output power, kW | 40 kW | 50 kW | 65 kW | 80 kW |
Range of anode voltage change | 40-150 kV |
Range of anode current change | 10-500 mA | 10-630 mA | 10-800 mA | 10-800 mA |
*Range of anode current change on request | | | | *10-1000 mA |
Range of electric charge, mAs | 0.4-600 mAs |
Range of exposure time change: | 0.001 ÷ 6 s |
**option: fluoroscopy function (RF version)
High-frequency single-phase generators with capacitor energy storage of the R212.1x NEBULA series:
These generators have a power of 32, 40 and 50 kW.
NEBULA generators are less demanding on the quality of the electrical network, which makes them ideal for use in conditions with unstable electrical networks. The rated supply current does not exceed 10A (maximum network power is 2.2 kVA).
Nebula series X-ray units can be powered by a combustion engine generator or connected to inverter systems with battery storage units of 4 kW or more.
Technical specifications of the most commonly used NEBULA generators
| R212.12 | R212.13 | R212.14 |
Power supply | One phase, 230 V ±10%, 50 ±1 Hz |
Output power, kW | 32 kW | 40 kW | 50 kW |
Input current during energy accumulation (when charging capacitors) | No more than 16 A |
Range of anode voltage variation | 40-150 kV |
Range of anode current variation | 10-320 mA | 10-400 mA | 10-500 mA |
Range of electric charge, mAs | 0.4-380 mAs |
Range of change of exposure time | 0.001 ÷ 6 s |
All ODEL generators have additional characteristics
Types of X-ray tube protection: | Maximum load; Anode overheating protection; Anode rotation; Tube thermal switch; Filament overheating;Maximum voltage protection.
Three programming modes: | Three-point, kV/mA/hour;
Two-point, kV/mAs;
single-point, kV (when working with the automatic exposure control function of the NPP). |
Anatomical programming mode |
Automatic exposure control function of the NPP (the camera type is specified when ordering) |
Clinical dosimeter connection function |
X-ray generator exposure control function from the generator control panel or from an additional computer |
Display of dosimeter measurement results on the generator control panel to determine effective patient irradiation doses |
X-ray tube overload protection |
|
All ODEL generators are equipped with convenient touch-screen consoles (control panels) with a diagonal of 7 inches (10.4" on request).
Exposure control is possible in two ways: via the operator's computer or directly from the touch-screen console. In addition, all generators can be equipped free of charge.
ODEL generators can be equipped with a special interface for digital systems, designed for manufacturers of X-ray equipment.
For developers and manufacturers of digital X-ray systems, ODEL has the ability to manufacture a generator simulator capable of simulating electrical and digital signals for testing without a physical generator.
ODEL is a leader in in the production of X-ray generators, relying on more than 60 years of experience in this field. An innovative approach to the development and manufacture of high-quality products makes ODEL a reliable partner for medical institutions. Thanks to a wide range of generators, medical institutions can choose the optimal equipment that meets their needs, ensuring the improvement of diagnostic processes and the quality of medical services.
High-frequency X-ray generators manufactured by ODEL SRL meet the requirements of the Technical Regulations of Medical Products in Ukraine, which confirms their compliance with modern safety and efficiency standards.
Explanation of the information and advertising nature of the information posted on the site.
Dear visitors of our site. All information contained on the site is for informational and advertising purposes only. The information provided on the site is not exhaustive.Technical specifications may be changed or supplemented at any time.
This information cannot be used as official document, for example, for the preparation of the technical part of the tender documentation.
For more information, contact our experts. Contact Us >>
|